Myopia can be corrected by 3 different means, as follows:
Optical devices (ie, glasses, contact lenses)
Corneal refractive procedures (ie, radial keratotomy [RK], automated lamellar keratoplasty [ALK], photorefractive keratoplasty [PRK], laser-assisted in situ keratomileusis [LASIK])
Intraocular procedures (ie, clear lens extraction with or without lens implantation and the use of phakic intraocular lens [IOL] implants)
The important facets of each procedure are the ease of application, the accuracy, the period of recovery, the quality of vision, the long-term stability of the results, and the minor or major complications. Also important are the possibilities of the reversal of the procedure and the successful management of complications.
Each intraocular procedure has its advantages, in terms of ease of implantation and tissue reactions causing change of position, inflammation, degeneration, and rise of intraocular pressure (IOP).
LASIK is currently the most popular type of refractive surgery. It is safe and effective, and technology advances such as femtosecond bladeless LASIK have further improved visual outcomes. However, not all patients are good candidates for LASIK surgery, including patients with severe myopia, patients who have hypermetropia or astigmatism, patients with an unusually thin or irregularly shaped cornea, and patients with eye conditions such as keratoconus, pellucid marginal dystrophies, or dry eye.
Phakic IOL is preferable over LASIK surgery in most patients with severe myopia. In such patients, outcomes of phakic IOLs are superior to those of LASIK surgery in terms of both postoperative visual acuity and contrast sensitivity.
All the various phakic IOLs, whether angle supported, iris supported, or placed in the posterior chamber, provide good immediate postoperative results. However, frequent change in the designs of the angle-supported and the posterior chamber lenses makes conclusions about long-term stability difficult. The design of the iris claw lens has practically remained unchanged in the past 15 years.
Note the images below.
Compared to the corneal procedures, the intraocular procedures suffer from one glaring handicap, that is, patients with the lens implants have to be under careful supervision of the ophthalmic surgeon throughout their lives to prevent or treat any adverse development. The role of microtrauma or macrotrauma as a result of blinking, squeezing, and minor rubbing during the waking hours and involuntary hard rubbing during some phases of sleep, in producing tissue changes, cannot be overemphasized.
The future of phakic IOLs shall be determined by the newer techniques of corneal refractive surgery, especially the wave-guided ablations. Phakic IOLs cannot take care of preexisting astigmatism. Surgery might introduce astigmatism of its own. Also, with the passage of months and years, patients with phakic IOLs tend to miss detailed follow-up examinations. Situations do exist where phakic IOLs and corneal procedures can be combined to provide the best refractive results. Whether a phakic myopia IOL in a young patient will be a problem in future decades is still unknown.
Various phakic IOLs are available.
The Visian implantable collamer lens (ICL), marketed by Staar Surgical, is a posterior-chamber phakic IOL, meaning it is positioned behind the iris and in front of the crystalline lens. It received FDA approval in 2005 for correcting myopia ranging from -3.00 to -20.00 D. The Visian ICL is made of a soft biocompatible collagen copolymer. Owing to its flexibility, the lens can be folded during implantation, requiring only a small surgical incision.
The Verisyse (Abbott Medical Optics) is an anterior-chamber phakic IOL, meaning it is positioned in front of the iris. In 2004, the Verisyse phakic IOL received FDA approval for correcting moderate to severe myopia ranging from -5.00 to -20.00 D. The Verisyse lens is made of medical-grade plastic (polymethylmethacrylate [PMMA]) and is rigid in form. In Europe, it is approved and marketed under the trade name Artisan. Verisyse IOLs are not typically noticeable in the eye, although they may be visible to patients upon close inspection with a mirror.. This iris claw lens has been in use in India by Professor Dr. Daljit Singh by the name of Singh’s modification of Jan Worst’s lens since the late 1970s. Dr. Singh has implanted this lens in more than 100,000 eyes over the past 30 years.
The Visian ICL and Verisyse phakic IOL are FDA approved to correct myopia only.
The phakic myopia lens was introduced by Strampelli and later popularized by Barraquer in the late 1950s. The design was a biconcave angle-supported lens. These lenses were abandoned following serious angle- and endothelium-related complications. In the mid 1980s, Dveli restarted phakic myopia lenses with 4 soft angle-supported loops. Baikoff introduced a myopia lens with Kelman-type haptics. This design had many problems, leading to its design modification a number of times. Fyodorov introduced the concept of a soft phakic lens in the space between the iris and the anterior surface of the crystalline lens. Earlier, the material used was silicone; now, the material used is collamer. Note the image below.
Worst, who introduced the iris claw lens in 1977, implanted an opaque iris claw lens in the phakic eye of a patient who had unbearable diplopia in 1979. Fechner and Worst introduced a phakic myopia lens of iris claw design in 1986. According to Ophthec, the maker of this lens (now called Artisan), more than 16,000 such lenses have been implanted worldwide in phakic myopes. During the same period, more than 250,000 iris claw lenses have been implanted in aphakes, which suggested that the design is well tolerated by the iris, where the lens is fixated.
Note the images below.
During the past 20 years, the coauthor has implanted more than 160,000 iris claw lenses (ie, Artisan lenses) in his hospital (ie, Daljit Singh Eye Hospital, Amritsar, India); during this same period, the author has implanted approximately 20,000 lenses. In India, also during this same period, approximately 100,000 lenses have been implanted. Ophthec reports that more than 15,000 lenses are implanted in Europe every year. [1]
Myopia is a common refractive error, which exists from a young age. A unilateral myopia, with or without amblyopia, might remain undiscovered for a long time. The treatment of unilateral myopia is not easy. Since the vision is very good in the other emmetropic eye, the child is not impressed by the glass or the contact lens for the affected eye because the child prefers to use the nonaffected eye. Most parents give up all efforts out of sheer frustration, and the magnitude of wasted sight is immense.
While there is some experience with such modalities as the excimer laser for use as PRK or LASIK and the newly designed phakic IOLs, they have been used in adult patients, and there is little or no experience in the group of young patients who need the treatment. [2, 3] Slight or moderate myopia is hardly a problem as far as the vision is concerned. These patients do extremely well with glasses or contact lenses. However, high myopes do experience serious handicaps, both cosmetic and visual, for which surgery becomes a matter of importance.
Myopia is not merely a refractive problem. The importance of regular retinal examination should not be overlooked.
Much remains unknown about the developing eye. It is known that myopia results when the refracting optics of the eye focus parallel rays from infinity to a point in front of the retina (relative to the length of the eyeball).
Newborns are moderately hyperopic, but they have a broad distribution of refractive errors. As the eye grows, there is a shift toward emmetropia. Perhaps, myopia represents an extension of the emmetropization process.
The pathophysiology differs in the 3 types of IOLs, the angle-supported, the iris-fixated, and the precrystalline varieties.
Two types of angle-supported lenses for use in phakic eyes are available. One has a Kelman-type haptic design, the other has a somewhat different design. The optic is biconcave. The lens is vaulted at 20°. The effective optic diameter is 4 mm in one design and 5 mm in the other design. Both are polymethyl methacrylate (PMMA) lenses. Note the image below.
The angle-supported lens becomes fixated somewhere in the angle structures. There cannot be a perfect size of the IOL. A well-fixed lens is supposed to rest its haptics on the scleral spur. In actuality, the haptics press against the corneoscleral trabeculae and the Schlemm canal and, sometimes, the blood vessels in the vicinity that overlie the scleral spur. The haptics impinge on the nerve endings in the angle of the anterior chamber. However, nothing is known about this interaction. The haptics press on the segmental blood supply of the iris, leading to ischemia and iris atrophy, which results in progressive ovalization of the pupil. The haptics can erode through the angle tissues and become lodged in the ciliary body.
A loose angle-supported lens can move around and damage the corneal endothelium. Tissue reactions and damage to the angle of the anterior chamber can cause breakdown of the blood-aqueous barrier, uveitis-glaucoma-hyphema (UGH) syndrome. [4] Anterior segment inflammatory pathology may find an echo in the development of cystoid macular edema. [5] Microtrauma and macrotrauma of any nature can accelerate the pathological changes in the angle.
Iris claw lenses also are made of PMMA; the overall length of the implant varies from 7.2-8.5 mm, the size of the optic varies from 5-6 mm. The optic is convexo-concave, with a maximum height of 0.96 mm. The lens also is vaulted at the haptic to clear the natural vault of the iris.
The haptics become fixed to the midperiphery of the iris through the medium of the claws, located on either side of the lens. The amount of iris engaged into the claw depends on the judgment of the surgeon at the time of surgery.
The size of the IOL precludes all angle-related complications. No pupil- or posterior pigment epithelium–related problems occur because at no time does the lens come into contact with either of them. The author and the coauthor have used these lenses extensively, and they are very satisfied with the results. A concern does exist regarding chronic inflammation as a result of continued compression of the iris tissue in the claws. The inclusion of excessive iris tissue in the claws during surgery can push the lens against the iris and the crystalline lens. This can interfere with the free circulation of the aqueous through the pupil, possibly resulting in the formation of posterior synechia and inflammation.
Micromovements, such as blinking and squeezing, do not bring together the endothelium of the cornea and the optic of the IOL. However, forcible rubbing for any reason has the potential to damage the endothelium. [6]
The phakic posterior chamber lens or the precrystalline lens is made of a soft material, such as silicone or collamer. The overall length varies from 11-13 mm. The central biconcave optical zone varies from 4.5-5.5 mm. The average thickness of the haptic is 60 µm. In an ideal lens implant situation, it is supposed to remain clear of the crystalline lens by 100-200 µm. The posterior chamber lens is sized empirically by adding 0.5 mm from the white-to-white corneal diameter.
The vaulting of the lens is produced by the elastic single piece lens getting lifted from the ciliary body. This puts some constant pressure, however small, on it. The vaulting may let it stay clear of the crystalline lens, but it physically pushes the iris anteriorly, a tissue normally in touch with the crystalline lens in the central part. This unnatural constant contact pressure and friction might lay the foundation for ciliary body reactions and shedding of posterior pigment epithelium. It also may prevent free passage of aqueous across the pupil. A mistakenly larger sized lens will put more pressure on the iris and push it forward by what may be called the spinnaker effect (blowing sail of a sail boat).
The optimal size remains a matter of conjecture. A mistaken small size allows the lens to rub against the natural crystalline lens (causing cataract) and knock against the ciliary body (setting up uveal reaction) and the posterior surface of the iris (releasing the pigment). The free volume of the restricted posterior chamber space is encroached upon by the implanted IOL and an increase in the size of the natural crystalline lens with age. If the peripheral iridectomy becomes blocked, iris bombé and consequent angle-closure glaucoma will occur. Some of the developments occurring behind the iris cannot be visualized clinically. They can only be speculated.
During blinking, squeezing, and rubbing, the results of pressure and friction between the IOL and the surrounding tissues are unknown. Even if the frictional force is very small, it is bound to continue for life. When shed from the iris and ciliary processes, the pigment may lead to glaucoma. Patients with diabetes can have problems. This disease causes changes in the posterior pigment epithelium of the iris, which may cause excessive shedding of pigment. An inflammatory process can bind the lens to the iris, the ciliary body, or even the crystalline lens. An intermittent or a continuous touch with the anterior lens capsule can produce lens opacification. Sometimes, the presence of the artificial lens in the posterior chamber can crowd the angle of the anterior chamber, leading to glaucoma.
In all phakic IOLs, increased crystalline lens size with increasing age and cataract formation leading to a decrease in the depth of the anterior chamber and crowding in the posterior chamber tend to exaggerate the pathologic processes. While the results of phakic IOLs are highly predictable, long-term data are limited.
The prevalence of myopia is approximately 20% in the United States. This incidence rate frequently varies with age, sex, race, ethnicity, occupation, environment, and other factors in various sampled populations. The condition is more common in central and eastern Europe than in northern Europe, Britain, and the United States.
The incidence of simple myopia is quite high since it occurs as a normal chance variant in the biological series, which include emmetropia and hypermetropia. In comparison, high and degenerative myopia are relatively rare. It has been estimated that myopia of more than -6.00 diopters (D) represents 27-32% of the myopic population and more than -8.00 D represents 6-18% of the myopic population.
Unilateral high myopia (more than about -6.00 D) of early onset can cause severe amblyopia. Severe symmetric refractive error (isometropia) may cause bilateral amblyopia of mild-to-moderate degree. However, myopia, even when extreme, rarely causes bilateral amblyopia because the sharply focused images of objects held close to the eyes support normal visual development.
Race exercises a considerable influence over myopia. High degrees with degenerative changes are very common in certain races, such as Chinese, Japanese, Arab, and Jewish persons. Myopia is uncommon in black, Nubian, and Sudanese persons. The variation probably is due more to heredity than habit.
Sex appears to have an influence on the incidence. Although in the lower degrees of myopia, the sexes seem to be affected equally, with a probable excess in males; females are more prone to the higher degrees and to degenerative changes. Surgical correction of myopia in girls assumes significance in certain societies where wearing of glasses and/or contact lenses is not looked upon kindly.
Age at which surgery is performed is of great importance. The ideal age should be at around age 18 years when the refraction stabilizes. However, in specific circumstances, in the interest of the minor patient, the parents and the surgeon can opt to perform phakic lens implantation at an earlier age.
Clinical manifestations are as follows:
Defective uncorrected vision
Defective corrected vision – Myopic retinal degeneration and deprivation amblyopia
Strabismus
Nystagmus
Clinical findings are as follows:
The eyeball may be normally placed, prominent, or deeply set.
The cornea may have a normal diameter, or some degree of microcornea or megalocornea may be present.
Axial length – 20 mm to greater than 30 mm
Keratometry reading – 38-50 D
Depth of the anterior chamber – 2.5-4 mm
Myopia may be moderate or severe, even going beyond -20.0 D.
IOP should be normal, and the patient should not be under treatment for any kind of glaucoma.
Strabismus
Nystagmus
Fundus examination may show various degrees of lattice degeneration, with or without one or more holes. The macular area may show disturbed macular reflex, chorioretinal atrophy, or posterior staphyloma.
Visual field defects of myopia may be present.
History findings are as follows:
Deteriorating vision
Difficulty in handling glasses or contact lenses; intolerance to contact lenses
Optical problems in daily life, especially during driving
Cosmetic concerns of the patient
Problems in such professions as sports, stage, and service regulations
Physical findings are as follows:
All patients should undergo a complete ophthalmic examination.
Manifest and cycloplegic refraction
Uncorrected visual acuity
Spectacle and/or contact lens corrected visual acuity
Slit lamp examination of the anterior segment and ocular adnexa
IOP
Pupil size measurement under scotopic conditions
Corneal endothelial cell count with specular endothelial microscopy
Biometry to calculate axial length of the eyeball and the anterior chamber
White-to-white corneal diameter measurement, if contemplating angle-supported or posterior chamber implants
Videokeratography and keratometry
Fundus examination by indirect ophthalmoscopy
Field charting
Indications include unilateral or bilateral, moderate or severe myopia; cosmetic needs; and professional and service requirements.
The current practical options for the cornea are PRK and LASIK; for intraocular implantation procedures, an angle-supported lens, an iris-supported lens, or a posterior chamber lens are practical options. Surgeons in different parts of the world may have differing opinions about these 3 lenses.
When planning for an IOL implant in phakic myopes, consider the following:
What is the minimum age at which the lens is to be implanted?
What is the minimum or the maximum refractive error to be treated?
What should be the lowest limit for anterior chamber depth?
What is the lowest corneal diameter at which lens implantation will be refused?
How accurate is the white-to-white diameter on the basis of which the length of an implant lens is to be derived?
What is the smallest size of the lens available?
How can the risk of complications be minimized? What are those complications? What are the chances of occurrence?
The final decision to do lens implantation comes after careful contemplation and detailed consultations and discussions.
The author and the coauthor are very interested in amblyopia and, to date, have helped more than 10,000 children and young adults with various forms of amblyopia, including those with amblyopia due to high myopia (unilateral and bilateral).
A new study by Alio et al shows promise in treating anisometropic amblyopia with phakic IOLs in adults. [7] The study reported a mean gain in vision of 3 lines, with a range of 0-7 lines. No patient lost any vision. PRK and LASIK have previously been studied to correct anisometropic amblyopia. In comparison to these studies, the visual results were similar after phakic IOL implantation for amblyopia. However, phakic IOL implantation may be a better option than LASIK or PRK because this study’s population had a much higher initial spherical equivalent. While effective in adults, phakic IOLs—in the right size—might work even better in children.
These IOLs may now have a new niche in the correction of amblyopia in adults. Alio et al evaluated the use of phakic IOLs to correct amblyopia in an adult population, with surprisingly good results. [7]
According to Alio et al, “This improvement is accounted for by the magnification on the retina caused by the intraocular lens, as opposed to the minimization induced by optical correction at the spectacle plane and the decrease in the spot size resulting from optical aberrations. This improvement was related to optical factors involved in the correction of the high myopia with a phakic IOL.”
PRK and LASIK have previously been studied to correct anisometropic amblyopia and have had some success. According to Alio et al, “If excimer laser procedures can improve amblyopia in adults, phakic IOLs should be capable of doing so as well. This, along with the advantages of phakic IOLs regarding better quality of vision and lack of induction of aberrations resulting from corneal laser ablation, makes them an excellent alternative for the treatment of anisometropic amblyopia.”
Fifty-nine eyes of 48 patients with anisometropic amblyopia underwent analysis by Alio and colleagues. They received angle-supported phakic IOLs (Domilens-Chiron, Lyon, France). Thirty-seven patients were unilaterally implanted, and 11 patients were bilaterally implanted.
According to Alio et al, “After implantation of a phakic IOL, the visual acuity of myopic patients with anisometropic amblyopia showed a significant increase. This improvement is accounted for by the magnification on the retina caused by the intraocular lens, as opposed to the minimization induced by optical correction at the spectacle plane and the decrease in spot size resulting from optical aberrations.”
Specifically, the mean gain in visual acuity was 3 lines, with a range of 0-7 lines. No eyes lost vision. Further, 54 eyes (91.5%) gained at least 1 line of visual acuity.
According to Alio et al, “Our analysis … does not show evidence of neuroprocessing related to underlying mechanics in the rehabilitation of amblyopia in these anisometropic adult patients; instead, this improvement was related to optical factors involved in the correction of the high myopia with a phakic IOL.”
Comparing these results with those from LASIK or PRK for amblyopia, the advantages of phakic IOLs are evident. As stated by Alio et al, “We obtained visual outcomes in our study group similar to those reported with other refractive procedures. Mean preoperative spherical equivalent was much higher in our series; thus, phakic IOL implantation was a better surgical option than LASIK or PRK.”
Karl Stonecipher, MD, Medical Director, TLC Carolina, Greensboro, NC, agreed that phakic IOLs have a role to play in amblyopia correction but suggested better results could be obtained if they are implanted earlier in life prior to the development of the amblyopia. [8]
“I agree totally with the findings of Dr. Alio’s group and other reports of success with LASIK and refractive lensectomies that have been presented and published. Those studies show that improving the optics, as the study suggests, improves the overall visual function. I think it would be great if we could just interrupt the process earlier. Most older studies show you’re not going to significantly change the course of the problem after nine years of age. Yet, in these anisometropic amblyopic patients, any benefit can add to the functionality of the patient.”
Unfortunately, current phakic IOLs are too large for young children. So other more conventional methods, such as glasses, contact lenses, atropine, and patching, may have to do in the meantime. Additionally, reports of LASIK for anisometropia in children have appeared and shown successful outcomes.
Stonecipher noted, if phakic IOLs were made for children to treat anisometropic amblyopia, that would probably be a relief for parents who have to deal with contact lenses, patching, and the use of atropine drops. Parents often get tired of these methods to correct amblyopia because of their child’s complaints.
However, one potential problem with a smaller phakic IOL would be the fact that it would have to be explanted at some point and a larger IOL fitted or another refractive procedure performed as the eye grows. Further, putting kids to sleep to perform the phakic IOL procedure is also a risk, Stonecipher said.
Alio et al noted in their study that there is indeed room for improvement in amblyopia correction for children. Success rates of conventional methods, such as atropine and occlusion, range from 63-83%, respectively.
The following anatomical features involved in phakic posterior chamber lens implantation are important: the space available for the implanted lens, the structures with which the lens will intimately contact, and the effect of age on the dimensions of various involved structures.
The pupillary margin normally rests on the crystalline lens. The contact is maximum in a middilated condition. The posterior chamber, which has a volume of 65 µL, is a triangular space on cut section. The base is toward the periphery, and the apex is toward the pupillary margin (where the chamber depth is zero). Nothing is known about the variations of this space and its relationship with age, the depth of the anterior chamber, or with refraction.
Anteriorly, there is a floppy iris about 0.5 mm in thickness; the thickness does not change throughout life. Posteriorly, there is the firm crystalline lens, which has a volume of 140 µL at birth. The volume increases to 163 µL in the 30s and to 240 µL in the 80s, a change of 100 µL.
The anterior chamber depth decreases by 7% every decade. It is the increasing size of the crystalline with age that causes shallowing of the anterior chamber. At the same time, it is not unreasonable to assume that the restricted posterior chamber space is also progressively encroached upon by the increasing volume of the crystalline lens. By the time the patient is in the seventh decade, the space is nothing more than a mere slit. In the case of a posterior chamber lens, the thickest part of the implant, the optic, occupies the shallowest or the zero space.
If a plate haptic lens has to stay clear of the crystalline lens, it should vault in the central area. This can happen only if the haptic rests strongly on the ciliary processes and bows forward. Staying clear of the crystalline lens can lead to rubbing against the posterior pigment epithelium. It also means impinging on the ciliary epithelium of the ciliary processes. If the ciliary epithelium sheds, then the implanted lens will further touch the ciliary vasculature. The ciliary capillary endothelium has fenestrations of 30-100 µm, which are permeable to plasma proteins and tracer elements.
Lying between the crystalline lens and the iris, the phakic posterior chamber lens produces resistance to the flow of aqueous. The increasing volume of the crystalline lens with age encroaches on the posterior chamber volume. The crystalline lens volume increases greatly, from 150 µL to 240 µL, in a matter of 60 years.
The average anterior chamber depth is 3.15 mm (2.6-4.4 mm). The volume of the anterior chamber is 250 µL, which decreases by 7.5% per decade.
The iris is 0.5 mm thick at the root and 0.6 mm at the collarette. An iris claw lens is attached to the peripheral anterior surface of the iris by pushing a fold of the iris into the 2 claws of the lens. Consider the following 3 points: the space available around the lens and the distance from the corneal endothelium and the crystalline lens; the anatomy of the iris, especially the vasculature, as it is fixed in the claws of the lens; and the pupil movements and the friction between the iris and the phakic iris claw lens.
The posterior surface of the IOL is concave and cannot touch the crystalline lens. There is a respectable distance between the various parts of the lens and the corneal endothelium. The maximum height of the optic, which is in the center, is less than 1 mm. The haptic of the lens in the periphery is 0.18 mm. With age, the growth of the crystalline lens tends to reduce the depth of the anterior chamber. The maximum width of the implant lens is 8.5 mm, which allows it to remain away from the structures of the angle of the anterior chamber.
The vasculature of the iris is peculiar. The vascular endothelium of the human iris is not fenestrated. The endothelial cells of the iris vessels are joined by 2 types of intercellular junctions, the zonular tight junctions and the gap junctions. The vessels are covered in layers in the following order:
Pericytes
0.5-3 µm wide basal lamina
7-µm zone of sparse, longitudinally directed collagen fibers
Granular ground substance
Another 10 µm-wide connective tissue layer
Vessels that are located in the more cellular parts of the stroma (eg, anterior border layer) are invested in thicker and more cellular adventitia. These vascular peculiarities explain why the claw lens can grip the iris fold so well. Friction between the iris claw lens and the anterior surface of the iris is possible at the immediate vicinity of the 2 claws as well as along the edge of the lens. As observed during the past 25 years, an iris claw lens is well tolerated in aphakic eyes. Phakic eyes are different, and surgeons must be aware of any degenerative or inflammatory response. Furthermore, phakic lenses are being implanted in younger patients, and these patients will need to be observed beyond the lifetime of many of their surgeons.
The angle of the anterior chamber is another place where phakic angle-supported lenses are made to rest their footplates. The tissues involved are the corneoscleral trabeculae, the ciliary body, and the periphery of the iris. In the depth of the trabecular meshwork, there is the Schlemm canal, stray blood vessels in its vicinity, and the scleral spur. The scleral spur is deeper to the Schlemm canal, and it ends at a few micrometers wide tip under the posterior part of the corneoscleral trabeculae. The recess of the angle does not end at the level of the scleral spur but further posteriorly.
The major arterial circle is situated in the anterior part of the ciliary body. From this circle arise branches that go to the root of the iris anteriorly and the ciliary processes posteriorly. The endothelium of the capillaries in the ciliary body and the processes has fenestrations of 30-100 µm, which are permeable to plasma proteins and tracer elements. The arteries to the iris arise along with the branches to the ciliary processes. The vessels travel toward the pupillary margin without anastomosing, that is, they are more or less end arteries.
Contraindications include the following:
Myopia other than axial
Evidence of nuclear sclerosis or developing cataract
History of uveitis
Presence of anterior or posterior synechiae
Corneal dystrophy
Glaucoma or IOP higher than 20 mm Hg
Personal or family history of retinal detachment
Diabetes mellitus
Anterior chamber depth less than 2.75 mm
Some of the above contraindications are relative on the discretion of the surgeon and the needs of the patients.
Relative contraindications include the following:
The patient should not rub the eye. Young children who cannot follow these instructions should not be implanted with a phakic IOL.
The smallest available posterior chamber phakic lens is of 11 mm. The length of the lens is calculated by adding 0.5 mm to the white-to-white limbal diameter. The minimum white-to-white diameter should be 11 mm. Any degree of microcornea from this size is a contraindication. In the case of an iris claw lens, it is possible to have customized, smaller lenses. While the normal phakic lens is 8.5 mm wide, the iris claw lens may be made as small as 6 mm, thus greatly extending its application.
The presence of amblyopia should not be a contraindication for the following purposes:
To reduce the power of the glasses
To provide a greater freedom of movement
Later, to attempt to improve the eyesight with pleoptic exercises
Anterior chamber depth is an important consideration for all 3 types of lenses, whether it is angle-supported, iris claw, or posterior chamber lenses. A depth of less than 2.75 mm is a contraindication. The angle-supported or the posterior chamber lens may cause crowding of the angle, but the iris claw lens will encroach on the central depth of an already shallow anterior chamber.
Hassaballa MA, Macky TA. Phakic intraocular lenses outcomes and complications: Artisan vs Visian ICL. Eye (Lond). 2011 Oct. 25(10):1365-70. [Medline]. [Full Text].
Rosman M, Alió JL, Ortiz D, Pérez-Santonja JJ. Refractive stability of LASIK with the Visx 20/20 excimer laser vs ZB5m phakic iol implantation in patients with high myopia (>-10.00 d): a 10-year retrospective study. J Refract Surg. 2011 Apr. 27(4):279-86. [Medline].
Barsam A, Allan BD. Excimer laser refractive surgery versus phakic intraocular lenses for the correction of moderate to high myopia. Cochrane Database Syst Rev. 2012 Jan 18. 1:CD007679. [Medline].
Klaproth OK, Rehrmann J, Kohnen T. Dynamic positional change and defocus curve of a phakic foldable anterior-chamber angle-supported intraocular lens during accommodation. Ophthalmology. 2013 Jul. 120(7):1373-9. [Medline].
Alio JL, Abbouda A, Peña-Garcia P. Anterior segment optical coherence tomography of long-term phakic angle-supported intraocular lenses. Am J Ophthalmol. 2013 Nov. 156(5):894-901.e2. [Medline].
Na KS, Jeon S, Joo CK. Effect of intraoperative manipulation during iris-claw phakic IOL implantation on endothelium. Can J Ophthalmol. 2013 Aug. 48(4):259-64. [Medline].
Alió JL, Ortiz D, Abdelrahman A, de Luca A. Optical analysis of visual improvement after correction of anisometropic amblyopia with a phakic intraocular lens in adult patients. Ophthalmology. 2007 Apr. 114(4):643-7. [Medline].
Stonecipher KG, et al. EW Roundtable:The Unhappy Postoperative Refractive Patient. Eye World. May 2002.
Sedaghat M, Zarei-Ghanavati M, Ansari-Astaneh MR, Patel V, Sikder S. Evaluation of sterile uveitis after iris-fixated phakic intraocular lens implantation. Middle East Afr J Ophthalmol. 2012 Apr-Jun. 19(2):199-203. [Medline]. [Full Text].
Trindade F, Pereira F, Cronemberger S. Ultrasound biomicroscopic imaging of posterior chamber phakic intraocular lens. J Refract Surg. 1998 Sep-Oct. 14(5):497-503. [Medline].
Zaldivar R, Davidorf JM, Oscherow S, Ricur G, Piezzi V. Combined posterior chamber phakic intraocular lens and laser in situ keratomileusis: bioptics for extreme myopia. J Refract Surg. 1999 May-Jun. 15(3):299-308. [Medline].
Kohnen T. Searching for the perfect phakic intraocular lens. J Cataract Refract Surg. 2000 Sep. 26(9):1261-2. [Medline].
Pérez-Santonja JJ, Alió JL, Jiménez-Alfaro I, Zato MA. Surgical correction of severe myopia with an angle-supported phakic intraocular lens. J Cataract Refract Surg. 2000 Sep. 26(9):1288-302. [Medline].
Allemann N, Chamon W, Tanaka HM, Mori ES, Campos M, Schor P, et al. Myopic angle-supported intraocular lenses: two-year follow-up. Ophthalmology. 2000 Aug. 107(8):1549-54. [Medline].
Alio JL, de la Hoz F, Perez-Santonja JJ, Ruiz-Moreno JM, Quesada JA. Phakic anterior chamber lenses for the correction of myopia: a 7-year cumulative analysis of complications in 263 cases. Ophthalmology. 1999 Mar. 106(3):458-66. [Medline].
Aguilar-Valenzuela L, Lleo-Perez A, Alonso-Munoz L, Casanova-Izquierdo J, Perez-Molto FJ, Rahhal MS. Intraocular pressure in myopic patients after Worst-Fechner anterior chamber phakic intraocular lens implantation. J Refract Surg. 2003 Mar-Apr. 19(2):131-6. [Medline].
Alio JL, de la Hoz F, Ismail MM. Subclinical inflammatory reaction induced by phakic anterior chamber lenses for the correction of high myopia. Ocular lenses for the correction of high myopia. Ocular Immunology and Inflammation. Swets & Zeitlinger: 1993. Vol 1: 219-223.
Ardjomand N, Kölli H, Vidic B, El-Shabrawi Y, Faulborn J. Pupillary block after phakic anterior chamber intraocular lens implantation. J Cataract Refract Surg. 2002 Jun. 28(6):1080-1. [Medline].
Arne JL, Lesueur LC. Phakic posterior chamber lenses for high myopia: functional and anatomical outcomes. J Cataract Refract Surg. 2000 Mar. 26(3):369-74. [Medline].
Asano-Kato N, Toda I, Hori-Komai Y, Sakai C, Fukumoto T, Arai H, et al. Experience with the Artisan phakic intraocular lens in Asian eyes. J Cataract Refract Surg. 2005 May. 31(5):910-5. [Medline].
Assetto V, Benedetti S, Pesando P. Collamer intraocular contact lens to correct high myopia. J Cataract Refract Surg. 1996 Jun. 22(5):551-6. [Medline].
Assil KK. The ARTISAN myopia lens: interim results of the US FDA clinical study. Available at http://www.ophthalmic hyperguide.com. Accessed: Dec 2005.
Baikoff G, Arne JL, Bokobza Y, Colin J, George JL, Lagoutte F, et al. Angle-fixated anterior chamber phakic intraocular lens for myopia of -7 to -19 diopters. J Refract Surg. 1998 May-Jun. 14(3):282-93. [Medline].
Baikoff G, Colin J. Intraocular lenses in phakic eyes. Ophthalmol Clin North Am. 1992. 5:789-795.
Barraquer J. Anterior chamber plastic lenses. Results of and conclusions from five years’ experience. Trans Ophthalmol Soc U K. 1959. 79:393-424. [Medline].
Benedetti S, Casamenti V, Marcaccio L, Brogioni C, Assetto V. Correction of myopia of 7 to 24 diopters with the Artisan phakic intraocular lens: two-year follow-up. J Refract Surg. 2005 Mar-Apr. 21(2):116-26. [Medline].
Budo C, Hessloehl JC, Izak M, Luyten GP, Menezo JL, Sener BA, et al. Multicenter study of the Artisan phakic intraocular lens. J Cataract Refract Surg. 2000 Aug. 26(8):1163-71. [Medline].
Colin J. Bilensectomy: the implications of removing phakic intraocular lenses at the time of cataract extraction. J Cataract Refract Surg. 2000 Jan. 26(1):2-3. [Medline].
Colin J, Robinet A, Cochener B. Retinal detachment after clear lens extraction for high myopia: seven-year follow-up. Ophthalmology. 1999 Dec. 106(12):2281-4; discussion 2285. [Medline].
Dejaco-Ruhswurm I, Scholz U, Pieh S, Hanselmayer G, Lackner B, Italon C, et al. Long-term endothelial changes in phakic eyes with posterior chamber intraocular lenses. J Cataract Refract Surg. 2002 Sep. 28(9):1589-93. [Medline].
Dick HB, Kohnen T, Jacobi FK, Jacobi KW. Long-term endothelial cell loss following phacoemulsification through a temporal clear corneal incision. J Cataract Refract Surg. 1996 Jan-Feb. 22(1):63-71. [Medline].
Fechner PU. Cataract formation with a phakic IOL. J Cataract Refract Surg. 1999 Apr. 25(4):461-2. [Medline].
Fechner PU. Intraocular lenses for the correction of myopia in phakic eyes: short-term success and long-term caution. Refract Corneal Surg. 1990 Jul-Aug. 6(4):242-4. [Medline].
Fechner PU, Haigis W, Wichmann W. Posterior chamber myopia lenses in phakic eyes. J Cataract Refract Surg. 1996 Mar. 22(2):178-82. [Medline].
Fechner PU, Strobel J, Wichmann W. Correction of myopia by implantation of a concave Worst-iris claw lens into phakic eyes. Refract Corneal Surg. 1991 Jul-Aug. 7(4):286-98. [Medline].
Fechner PU, van der Heijde GL, Worst JG. The correction of myopia by lens implantation into phakic eyes. Am J Ophthalmol. 1989 Jun 15. 107(6):659-63. [Medline].
Fechner PU, Wichmann W. Correction of myopia by implantation of minus optic (Worst iris claw) lenses into the anterior chamber of phakic eyes. Eur J Implant Surg. 1993. 5:55-59.
Fyodorov SN, Zuew VK, Tumanyan NR, Suheil AJ. Clinical and functional follow-up of minus IOL implantation in high grade myopia. Oftalmochirurgia. 1993. 2:12-17.
Gonvers M, Othenin-Girard P, Bornet C, Sickenberg M. Implantable contact lens for moderate to high myopia: short-term follow-up of 2 models. J Cataract Refract Surg. 2001 Mar. 27(3):380-8. [Medline].
Jimenez-Alfaro I, Benitez del Castillo JM, Garcia-Feijoo J, Gil de Bernabe JG, Serrano de La Iglesia JM. Safety of posterior chamber phakic intraocular lenses for the correction of high myopia: anterior segment changes after posterior chamber phakic intraocular lens implantation. Ophthalmology. 2001 Jan. 108(1):90-9. [Medline].
Kashani AA. Phakic posterior chamber intraocular lenses for the correction of high myopia. J Refract Surg. 1996 May-Jun. 12(4):454-6. [Medline].
Koch DD. Enter with caution (editorial). J Cataract Refract Surg. 1996. 22:153-154.
Krumeich JH, Daniel J, Gast R. Closed-system technique for implantation of iris-supported negative-power intraocular lens. J Refract Surg. 1996 Mar-Apr. 12(3):334-40. [Medline].
Landesz M, van Rij G, Luyten G. Iris-claw phakic intraocular lens for high myopia. J Refract Surg. 2001 Nov-Dec. 17(6):634-40. [Medline].
Landesz M, Worst JG, Siertsema JV, van Rij G. Correction of high myopia with the Worst myopia claw intraocular lens. J Refract Surg. 1995 Jan-Feb. 11(1):16-25. [Medline].
Landesz M, Worst JG, Van Rij G, Houtman WA. Opaque iris claw lens in a phakic eye to correct acquired diplopia. J Cataract Refract Surg. 1997 Jan-Feb. 23(1):137-8. [Medline].
Malecaze FJ, Hulin H, Bierer P, Fournie P, Grandjean H, Thalamas C, et al. A randomized paired eye comparison of two techniques for treating moderately high myopia: LASIK and artisan phakic lens. Ophthalmology. 2002 Sep. 109(9):1622-30. [Medline].
Maloney RK, Nguyen LH, John ME. Artisan phakic intraocular lens for myopia:short-term results of a prospective, multicenter study. Ophthalmology. 2002 Sep. 109(9):1631-41. [Medline].
Menezo JL, Aviño JA, Cisneros A, Rodriguez-Salvador V, Martinez-Costa R. Iris claw phakic intraocular lens for high myopia. J Refract Surg. 1997 Sep-Oct. 13(6):545-55. [Medline].
Menezo JL, Cisneros A, Hueso JR, Harto M. Long-term results of surgical treatment of high myopia with Worst-Fechner intraocular lenses. J Cataract Refract Surg. 1995 Jan. 21(1):93-8. [Medline].
Menezo JL, Cisneros AL, Rodriguez-Salvador V. Endothelial study of iris-claw phakic lens: four year follow-up. J Cataract Refract Surg. 1998 Aug. 24(8):1039-49. [Medline].
Menezo JL, Martinez MC, Cisneros AL. Iris-fixated Worst claw versus sulcus-fixated posterior chamber lenses in the absence of capsular support. J Cataract Refract Surg. 1996 Dec. 22(10):1476-84. [Medline].
Menezo JL, Peris-Martinez C, Cisneros AL, Martinez-Costa R. Phakic intraocular lenses to correct high myopia: Adatomed, Staar, and Artisan. J Cataract Refract Surg. 2004 Jan. 30(1):33-44. [Medline].
Nuzzi G, Cantù C. Vitreous hemorrhage following phakic anterior chamber intraocular lens implantation in severe myopia. Eur J Ophthalmol. 2002 Jan-Feb. 12(1):69-72. [Medline].
Perez-Santonja JJ, Hernandez JL, Benítez del Castillo JM, Rodriguez-Bermejo C, Zato MA. Fluorophotometry in myopic phakic eyes with anterior chamber intraocular lenses to correct severe myopia. Am J Ophthalmol. 1994 Sep 15. 118(3):316-21. [Medline].
Pérez-Santonja JJ, Bueno JL, Meza J, García-Sandoval B, Serrano JM, Zato MA. Ischemic optic neuropathy after intraocular lens implantation to correct high myopia in a phakic patient. J Cataract Refract Surg. 1993 Sep. 19(5):651-4. [Medline].
Pérez-Santonja JJ, Bueno JL, Zato MA. Surgical correction of high myopia in phakic eyes with Worst-Fechner myopia intraocular lenses. J Refract Surg. 1997 May-Jun. 13(3):268-81; discussion 281-4. [Medline].
Pérez-Santonja JJ, Iradier MT, Benítez del Castillo JM, Serrano JM, Zato MA. Chronic subclinical inflammation in phakic eyes with intraocular lenses to correct myopia. J Cataract Refract Surg. 1996 Mar. 22(2):183-7. [Medline].
Pérez-Santonja JJ, Iradier MT, Sanz-Iglesias L, Serrano JM, Zato MA. Endothelial changes in phakic eyes with anterior chamber intraocular lenses to correct high myopia. J Cataract Refract Surg. 1996 Oct. 22(8):1017-22. [Medline].
Pérez-Torregrosa VT, Menezo JL, Harto MA, Maldonado MJ, Cisneros A. Digital system measurement of decentration of Worst-Fechner iris claw myopia intraocular lens. J Refract Surg. 1995 Jan-Feb. 11(1):26-30. [Medline].
Rosen E, Gore C. Staar Collamer posterior chamber phakic intraocular lens to correct myopia and hyperopia. J Cataract Refract Surg. 1998 May. 24(5):596-606. [Medline].
Ruiz-Moreno JM, de la Vega C, Ruiz-Moreno O, Alió JL. Choroidal neovascularization in phakic eyes with anterior chamber intraocular lenses to correct high myopia. J Cataract Refract Surg. 2003 Feb. 29(2):270-4. [Medline].
Sanders DR, Brown DC, Martin RG, Shepherd J, Deitz MR, DeLuca M. Implantable contact lens for moderate to high myopia: phase 1 FDA clinical study with 6 month follow-up. J Cataract Refract Surg. 1998 May. 24(5):607-11. [Medline].
Senthil S, Reddy KP. A retrospective analysis of the first Indian experience on Artisan phakic intraocular lens. Indian J Ophthalmol. 2006 Dec. 54(4):251-5. [Medline].
Steinert RF, Hersh PS. Spherical and aspherical photorefractive keratectomy and laser in-situ keratomileusis for moderate to high myopia: two prospective, randomized clinical trials. Summit technology PRK-LASIK study group. Trans Am Ophthalmol Soc. 1998. 96:197-221; discussion 221-7. [Medline].
Stulting RD, John ME, Maloney RK, Assil KK, Arrowsmith PN, Thompson VM. Three-year results of Artisan/Verisyse phakic intraocular lens implantation. Results of the United States Food And Drug Administration clinical trial. Ophthalmology. 2008 Mar. 115(3):464-472.e1. [Medline].
Vander Heijde GL. Some optical aspects of implantation of an intra ocular lens in a myopic eye. Eur J Implant Refract Surg. 1989. 1:245-8.
Wiechens B, Winter M, Haigis W, Happe W, Behrendt S, Rochels R. Bilateral cataract after phakic posterior chamber top hat-style silicone intraocular lens. J Refract Surg. 1997 Jul-Aug. 13(4):392-7. [Medline].
Zaldivar R, Davidorf JM, Oscherow S. Posterior chamber phakic intraocular lens for myopia of -8 to -19 diopters. J Refract Surg. 1998 May-Jun. 14(3):294-305. [Medline].
Arun Verma, MD Senior Consultant, Department of Ophthalmology, Dr Daljit Singh Eye Hospital, India
Disclosure: Nothing to disclose.
Daljit Singh, MBBS, MS, DSc † Professor Emeritus, Department of Ophthalmology, Guru Nanak Dev University; Director, Daljit Singh Eye Hospital, India
Daljit Singh, MBBS, MS, DSc is a member of the following medical societies: All India Ophthalmological Society, American Society of Cataract and Refractive Surgery, Indian Medical Association, International Intra-Ocular Implant Club, Intraocular Implant and Refractive Society, India
Disclosure: Nothing to disclose.
Francisco Talavera, PharmD, PhD Adjunct Assistant Professor, University of Nebraska Medical Center College of Pharmacy; Editor-in-Chief, Medscape Drug Reference
Disclosure: Received salary from Medscape for employment. for: Medscape.
Louis E Probst, MD, MD Medical Director, TLC Laser Eye Centers
Louis E Probst, MD, MD is a member of the following medical societies: American Academy of Ophthalmology, American Society of Cataract and Refractive Surgery, International Society of Refractive Surgery
Disclosure: Nothing to disclose.
Hampton Roy, Sr, MD Associate Clinical Professor, Department of Ophthalmology, University of Arkansas for Medical Sciences
Hampton Roy, Sr, MD is a member of the following medical societies: American Academy of Ophthalmology, American College of Surgeons, Pan-American Association of Ophthalmology
Disclosure: Nothing to disclose.
Daniel S Durrie, MD Director, Department of Ophthalmology, Division of Refractive Surgery, University of Kansas Medical Center
Daniel S Durrie, MD is a member of the following medical societies: American Academy of Ophthalmology, Association for Research in Vision and Ophthalmology
Disclosure: Received grant/research funds from Alcon Labs for independent contractor; Received grant/research funds from Abbott Medical Optics for independent contractor; Received ownership interest from Acufocus for consulting; Received ownership interest from WaveTec for consulting; Received grant/research funds from Topcon for independent contractor; Received grant/research funds from Avedro for independent contractor; Received grant/research funds from ReVitalVision for independent contractor.
Phakic Intraocular Lens (IOL) for Myopia Correction
Research & References of Phakic Intraocular Lens (IOL) for Myopia Correction|A&C Accounting And Tax Services
Source